Scope

Root-zone behaviour is defined by more than pH and EC. FlavoRotor records solution temperature, dissolved oxygen when available, immersion timing, drainage, mixing time, reservoir volume, solution age and root architecture.

Temperature

Root-zone temperature can alter growth and soluble-solids measurements, with cultivar-dependent responses reported in lettuce.

Reservoir age and composition

Recycled solution can accumulate unwanted or slowly consumed ions while bulk EC remains near target.

Sequential immersion

The rotating geometry introduces periodic root wetting and drainage documented in the FlavoRotor system records. This is treated as an experimental factor and potential confounder rather than assumed to improve oxygenation or flavour.

Required measurements

  • solution temperature at defined locations and intervals;
  • reservoir volume and replacement events;
  • mixing-time validation after each dose;
  • root-zone exposure duration per revolution;
  • root images and root dry mass;
  • water and nutrient balance.

Coupled variables

Root-zone temperature changes oxygen solubility and root metabolism; pH changes nutrient speciation and availability; EC describes bulk conductivity but not individual ions; flow and immersion determine renewal around the root surface. These variables are therefore logged together and are not interpreted independently when they covary.

VariableControl purposeFailure mode to detect
Solution temperaturestable root-zone conditionheating, cooling or spatial gradients
Dissolved oxygenroot respiration supportlow oxygen after warming or biological load
pHdefined root-zone chemistrydrift, probe fouling or dosing overshoot
ECbulk concentration guardraildilution, concentration or ionic imbalance hidden by total EC
Immersion and drainagerepeatable wetting cycleunequal contact, retained liquid or blocked drainage